Data Item Details

Name
Ranges of the capital cost, fixed cost and WACC for selected technologies considered in the CONE calculations – 2021 (euros/kW, euros/kW/year and % respectively)
Source
ACER based on NRA data
Reference
Figure 19
Comment
Data from Belgium, the Czech Republic, Finland, Greece, Italy, Slovenia and Sweden and the common German-Luxembourg calculation.

Data item data can be filtered and exported as an Excel file.
The reason for exporting is asked during export once per session.




Fields to export

Technology Range of values Capital Cost (euros/kW) Fixed Cost (euros/kW/year) Weighted average cost of capital (%) Fixed cost of new entry - CONE (euros/kW/year)
PhotovoltaicMinimum value64.919.751.34453.93
BatteriesMaximum value2000.0039.597.50694.00
BatteriesMinimum value100.002.303.6055.46
CCGTMaximum value700.0030.008.07100.38
CCGTMinimum value450.008.805.6052.73
Demand responseMaximum value70.0031.9810.00164.46
Demand responseMinimum value0.550.003.600.58
ICE gasMaximum value1590.7053.437.50194.22
ICE gasMinimum value300.0015.007.0079.00
Large HydroMaximum value1200.0030.007.00270.69
Large HydroMinimum value600.004.003.1646.23
OCGTMaximum value1300.0066.0010.00117.93
OCGTMinimum value169.405.502.5019.42
PhotovoltaicMaximum value900.0025.0011.917331.32
Pumped HydroMinimum value2583.0046.0012.60281.34
Small HydroMaximum value5900.0061.007.00381.38
Small HydroMinimum value1500.0037.503.28336.57
Wind OffshoreMaximum value3800.00140.007.504046.50
Wind OffshoreMinimum value1475.2442.384.602053.19
Wind OnshoreMaximum value1800.0050.007.502721.00
Wind OnshoreMinimum value700.007.803.24380.00